All-Flo Pump’s All-Safe DRM (Diaphragm Rupture Management) product is now available globally, designed to alert pump operators in the event of a diaphragm rupture. The enclosed system provides two layers of protection: An early warning sensor, installed between the PTFE overlay and the backup diaphragm, detects a leak if the PTFE overlay becomes compromised.

The sensor alerts pump operators of the leak before the backup diaphragm is compromised and hazardous fluid enters the air section. A second, critical leak detection sensor is installed in the air section itself. Should both diaphragms become compromised, this sensor will detect fluid in the air section. Both the early warning and critical sensors can be configured to take a variety of actions should a leak be detected, such as turning on a warning light, sounding an audible alarm or triggering pump shut-off. The All-Safe DRM is powered by 120 VAC. The signal cord is available in 5-, 10-, 15- or 20-ft (1.5- to 6.1-m) lengths. www.all-flo.com